Author Archives: colinmac

Adding Arista vEOS images to UnetLab

Arista provides a number of VM type images that you can use. The one with the software forwarding plane is vEOS-lab. This image has all the control plane features of standard EOS from Arista, with a software dataplane – the downside to this is that features that rely on the hardware e.g. NAT aren’t available.

There are two files required to get a working vEOS switch. The vmdk file and the Aboot ISO. To create a working vEOS on 4.17.5M we need:

  • vEOS-lab-4.17.5M.vmdk
  • Aboot-veos-serial-8.0.0.iso

To create an image that UnetLab will recognise the following steps should turn the trick

  1. Create the directory for the version in question
  2. Copy the two files in there
  3. Convert the vEOS-lab-4.17.5M.vmdk to a qcow image
  4. Rename the Aboot ISO to cdrom.iso file
  5. All done – fire up your Lab and select Arista vEOS as the template
mkdir /opt/unetlab/addons/qemu/veos-4.17.4M/
/opt/qemu/bin/qemu-img convert -f vmdk -O qcow2 ./vEOS-4.17.5M.vmdk hda.qcow2
mv Aboot-veos-serial-8.0.0.iso /opt/unetlab/addons/qemu/veos-4.17.5M/cdrom.iso
rm ./vEOS-4.17.5M.vmdk
/opt/unetlab/wrappers/unl_wrapper -a fixpermissions

 

Painful update of Dell R710 BIOS

As mentioned in the previous post, I recently acquired an R710 as part of a homelab buildout. I’ve now spent the best part of a day trying to figure out why the Lifecycle Controller stopped working, after it updated the BIOS. I don’t particularily need it, but I know if I ignore it something will come back to bite me when I least expect it.

The one clue (after trying multiple Repair images) was that when the BIOS was booting it had a blank rev. e.g. under the Dell logo there was “BIOS Rev. ” and a blank space. Much google-fu later and it turns out that this generally happens if you try and jump too many BIOS revisions at once.

Since the upgrade was done by the Lifecycle Controller, and was from 6.0.4 -> 6.4.0 I didn’t expect this to be an issue, but there you go. The process to recover is actually fairly straightforward when you know how, and in fairness to Dell they have a huge amount of great information in their forums.

This is just the short and quick version of how to fix.

  1. Create a DOS USB disk using the instructions here: https://www.dell.com/support/article/ie/en/iebsdt1/SLN143196/how-to-create-a-bootable-usb-flash-drive-using-dell-diagnostic-deployment-package–dddp-?lang=EN
  2. Download as many revisions of the BIOS between the original release and the target and copy them to the USB drive too from here – you want the non-packaged version.
    14/03/2017  22:24         1,631,701 R710-060007C.exe
    14/03/2017  22:23         1,633,695 R710-060100C.exe
    14/03/2017  22:23         1,650,371 R710-060203C.exe
    14/03/2017  22:24         1,650,583 R710-060300C.exe
    14/03/2017  22:22         1,653,153 R710-060400C.exe

    NOTE: You might want to rename them to fit in DOS’ 8.3 filename limitation unless you like to try and guess what the ~ are hiding

  3. Reboot the server and hit F2 to access the boot options, then choose to boot from the USB stick
  4. When it has loaded, start with the older of the BIOS versions – in my case 6.0.7. If you get a warning about the platform not being recognised add the /forcetype flag after the executable name
  5. Repeat until you are on the BIOS version you were aiming for

At this point the Lifecycle Controller should come up and you can use it for the remainder of your platform/firmware updates

Updating an old firmware on a Dell R710

I recently purchased a Dell R710 as part of a buildout for my homelab, and as part of that process, wanted to update all the software. This consists of;

  • BIOS – running 6.0.4, current is 6.4 so not too bad
  • iDRAC – running 1.10, current is 2.85, so a good leap
  • PERC6 – no idea
  • Lifecycle Controller – no idea

Given that the only OS installed is ESXi I had a bit of googling to figure this one out.

In theory the Lifecycle Controller has an Platform Update option that will just do all this for you… unfortunately this seemed to be missing on mine.

To get everything up and running, the following process worked for me;

  1. Download, and extract the firmimg.d6 file from the iDRAC updater. This will allow your iDRAC to updated to something modern enough not to give certificate/security/browser errors. Use the iDRAC firmware update option to get this installed
  2. Use the iDRAC firmware update page to load the USC/LC repair package (.usc extension)
  3. Reload and the Lifecycle Controller will now have a Platform Update option – use that to update everything else via FTP from dells website

NOTE: The Lifecycle controller uses the inbuilt NIC rather then the iDRAC ethernet interface

Some PTP Essentials

This entry is part 2 of 2 in the series Precision Time Protocol

IEEE 1588 aims at creating a master-slave timing distribution model across PTP clocks. In IEEE 1588, a clock is a node that implements PTP. In that node, a “PTP port” is a physical, logical, or virtual interface supporting PTP and handling PTP communications. To define the state or function of the port, IEEE 1588 defines state machines as part of its Best Master Clock Algorithm [BMCA] process.

Best Master Clock Algorithm

The BMCA actually has two key functions in a clock. Based on the information received on its PTP Port(s), the BMCA of a clock will:

  • define the master-slave hierarchy of the PTP distribution
  • select the best master (the clock source that it will synchronise to)

NOTE: Be aware of the distinction between the port state and the master clock selection, though both are handled as part of BMCA.

The BMCA is designed in such a way that a local clock determines which of all the clocks (including itself) is the “best”, then it decides on the state of all the ports (master/slave/passive). Clocks do not negotiate who should be master or slave – instead each computes the state of it’s own ports. The algorithm, by design, avoids configurations with two masters, no masters, or ones that thrash.

 

PTP ports can be in 1 of 3 states (the above diagram only considers GM, Slave, and intermediate port states. The role and type of the intermediate clocks isn’t considered yet, simply assume that they run the BMCA);

  1. Master – providing timing information to downstream clocks
  2. Slave – learning timing from an upstream (master) clock
  3. Passive – preventing a loop in the PTP topology

The master port of a clock transmits its packet-based clock signal in the form of PTP messages to the slave port or another clock. Slave ports allow a clock to synchronise with the root of the hierarchy, the ultimate master clock e.g. the Grandmaster [GM] clock. A passive port prevents timing loops or conflicting master ports in the same hierarchy, when there are multiple valid transport network paths (consider an L3 network – no ports blocked due to STP). The state of the port, and the selected clock source (best master or master port) can change over time.

In a steady state network, the BMCA processed by the clocks establishes a hierarchy up to the root, i.e. a GM, and ultimately to slave clocks, the leaves of the hierarchy.

The BMCA will avoid creating timing loops through valid transport network paths e.g. ports that are not blocked by spanning tree. In the case of any changes e.g. device or link failure, the BMCA might have to re-establish the hierarchy and/or reselect the master.

How do we select the “best” clock?

The best master clock algorithm compares one clock to another by comparing datasets (my dataset, vs current best dataset, vs. the dataset just received) that represent those clocks. The table below shows the parameters used to compare any two PTP clocks.

GM Priority 1 Configurable
GM Class Like NTP Stratum
GM Accuracy Atomic Clock, GPS, NTP, Hand set, Internal Oscillator, etc.
GM  offsetScaledLogVariance Provided info from GM regarding PTP variance due to temp, etc.
GM Priority 2 Configurable
GM Identity Usually based on the MAC Address
Steps Removed Number of hops to GM. 0 for local clock
Identity of Senders Identity of parent clock. Same as self for single clock
Identity of Receiver Own Identity
Port number of the receiver Own port number

GM selection can be manipulated using Priority1 and Priority2 values. Typically a true Grand Master device (Meinberg, etc.) will have a low Priority1, with the Priority2 value used to select a preferred active Grand Master device.

We would expect devices with a stable clock (for example the -CL variant of Arista’s 7150s), close to the GMs in the hierarchy to have an intermediate Priority1 and 2 values e.g. 127 – this way they would only become the GM if both “true” GM devices fail.

Slave devices (servers, etc.) would have the highest Priority value configured e.g. 255 to ensure that they never become the GM for the timing domain.

PTP Domains

IEEE 1588 defines the idea of a PTP Domain. These domains can be used for different purposes, e.g. technical or administrative, at the convenience of the user.  The standard defines the protocol and rules but does not define usage. A PTP domain corresponds to one GM delivering its clock signal over the hierarchy established for that domain. Simply put, a PTP domain corresponds to a unique hierarchy of two or more clocks synchronised to the same GM.

The spec allows a clock device to support multiple domains, but a PTP port within that device can only be part of a single domain. Logically, because a PTP communication path is established between two PTP ports, a PTP path belongs to one PTP domain and can never span multiple PTP domains.

A transport network supports multiple PTP domains and a physical network interface can convey multiple PTP paths depending on vendor implementation. Remember, a PTP port is a logical description that can be translated into a physical or virtual interface in a clock implementation. The specification allows for a PTP port to be assigned to a physical port, a VLAN or a loopback interface.

A network or a clock device can support multiple domains on the condition that each domain remains separate. This separation can be physical or logical, as distinct communication networks, VLANs or clocks, and could lead to more complex and expensive design implementation, particularly for maintaining different timescales in single clocks.

Introduction to Precision Time Protocol (IEEE 1588)

This entry is part 1 of 2 in the series Precision Time Protocol

This is the first part of a multi-part series that will cover the basic concepts, terminology, behaviours, and applications of PTP.

PTP Goals

PTP was originally defined in the IEEE 1588-2002 standard, officially entitled “Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems” and published in 2002. In 2008, IEEE 1588-2008 was released as a revised standard; also known as PTP Version 2 [PTPv2], it improves accuracy, precision and robustness but is not backward compatible with the original 2002 version.

IEEE 1588 was designed to fill a niche that neither NTP nor GPS could fulfill by solving two problems:

  1. Local systems needing clock accuracy in the sub-microsecond range
  2. Systems needing synchronisation in areas that cannot afford the cost of a GPS receiver at each node, or that cannot receive GPS signals (consider an underground or windowless datacenter)

The origins of IEEE 1588 development come from test and measurement (instrumentation and data acquisition), industrial automation or power generation, and received strong support from the automation industry leading to the adoption of the IEEE 1588-2002 standard by the Industrial Electro-technical Commission [IEC] as IEEE/IEC 61588-2004.

Specific application domains and targets had driven first release of IEEE 1588 work. Applications (e.g. data acquisition, military instrumentation, industrial robots and high-speed printers) and their targets, had sufficient shared objective to define common criteria:

  • Achievable sub-microsecond accuracy (if required).
  • Operation over control localised areas, such as local area network [LAN], with no intent to cover Internet or wide area networks, but supporting a PTP system.
  • Administration-free operation allowing “plug-and-play” deployment of IEEE 1588 clocks
  • Designed for minimal resource requirement in devices supporting PTP (clock filtering or averaging might not be necessary).

Currently one of the main industries using PTP is the High-Frequency Trading [HFT], and financial sector, to ensure highly accurate timing and synchronisation for their market feeds and trading servers.

When reading the spec

Just to note, that as an IEEE spec, 1588 can be far more difficult to read than IETF/RFC documents. A key thing to note in this particular spec is that IEEE 1588 also specifies “the node, system, and communications properties necessary to support PTP” and proposes models of devices, called “clocks” that support the protocol and aim to help and enhance the transfer of packet-based timing references. In IEEE 1588 terms, a PTP system is a set of IEEE 1588 clocks with specialised functions to support the protocol, PTP.

For instance, specifications of an IEEE 1588 clock include some material, such as a port, that is not part of the protocol itself. However, the messages sent and received by each port of an IEEE 1588 clock and the resulting behaviour of that clock is part of the protocol. Nonetheless, the standard does not define any performance objective for transport network device or clock.

To simplify – a PTP clock is a device that runs the PTP protocol, and has one or more network interfaces

Migrating from OpenELEC 6.0.3 to 7.0.1

More of a note to myself but I was doing a major version upgrade of OpenELEC for the first time and hit a few snags, so wanted to note these is case anyone else hits the same issues.

Basic setup, and potential issues;

  1. OpenELEC 6.0.3 running on a RPi3
  2. Media server is accessible via SMB
  3. Video database is on the MySQL server rather then locally
  4. Using TV Headend as a PVR client

OpenELEC 6.0.3 running on a RPi3

OpenELEC will not automatically upgrade to a major new release for fear of breaking things. You are expected to trigger this yourself. The process is fairly straightforward to be honest.

To upgrade, copy the update file (.tar) for the platform you are using into the /storage/.update/ directory and reboot, then when it is up and running, reboot a second time.

Note: I’m assuming you have a backup before you start this 🙂

Media server is accessible via SMB

No problems with this part actually. The SMB configuration was done through OpenELEC (and stored in /storage/.kodi/userdata/sources.xml) so this was preserved through the upgrade.

Video database is on the MySQL server rather then locally

This part caused some problems, as I’d forgotten that I had the permissions for kodi locked down. When starting up the ‘Film’ and ‘TV Shows’ categories weren’t visible.
/storage/.kodi/userdata/advancedsettings.xml was unchanged, so didn’t expect any problems in terms of client config:

  <videodatabase>
    <type>mysql</type>
    <host>192.168.1.x</host>
    <port>3306</port>
    <user>kodi</user>
    <pass>MySecretPassword</pass>
  </videodatabase>

Taking a look at the kodi log file (stored in /storage/.kodi/temp/kodi.log) I could see where things were going wrong.

18:42:19   9.573155 T:1963802624   ERROR: Unable to open database: MyVideos99 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos99')
18:42:19   9.591171 T:1963802624   ERROR: Unable to open database: MyVideos98 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos98')
18:42:19   9.611773 T:1963802624   ERROR: Unable to open database: MyVideos97 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos97')
18:42:19   9.636495 T:1963802624   ERROR: Unable to open database: MyVideos96 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos96')
18:42:19   9.657456 T:1963802624   ERROR: Unable to open database: MyVideos95 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos95')
18:42:19   9.676188 T:1963802624   ERROR: Unable to open database: MyVideos94 [1044](Access denied for user 'kodi'@'192.168.1.%' to database 'MyVideos94')
18:42:19   9.705974 T:1963802624  NOTICE: Old database found - updating from version 93 to 99
18:42:19   9.711560 T:1963802624   ERROR: SQL: Can't create database for copy: 'MyVideos93' (1044)
18:42:19   9.716779 T:1963802624   ERROR: Unable to copy old database MyVideos93 to new version MyVideos99

The number that Kodi tags to the end of the database name e.g. MyVideos93, 93 indicates the database version. Part of the upgrade involves upgrading the database to whatever revision we are now on. Kodi will do this for you, but creates it as a new database which means that it has to have permissions to do so.

The base permissions I granted by default weren’t sufficient for this:

mysql> show grants for 'kodi'@'192.168.1.%' ;
+-----------------------------------------------------------------------------------------------------+
| Grants for [email protected].%                                                                                   |
+-----------------------------------------------------------------------------------------------------+
| GRANT USAGE ON *.* TO 'kodi'@'%' IDENTIFIED BY PASSWORD '*xxxx' |
| GRANT ALL PRIVILEGES ON `MyVideos93`.* TO 'kodi'@'192.168.1.%'                                                 |
+-----------------------------------------------------------------------------------------------------+

Granted full permissions to Kodi.

mysql> GRANT ALL PRIVILEGES ON *.*  TO 'kodi'@'192.168.1.%' ;
Query OK, 0 rows affected (0.00 sec)
mysql> flush privileges;
Query OK, 0 rows affected (0.00 sec)

mysql> show grants for 'kodi'@'192.168.1.%';
+------------------------------------------------------------------------------------------------------------------------+
| Grants for [email protected].%                                                                                            |
+------------------------------------------------------------------------------------------------------------------------+
| GRANT ALL PRIVILEGES ON *.* TO 'kodi'@'192.168.1.%' IDENTIFIED BY PASSWORD '*xxxx' |
| GRANT ALL PRIVILEGES ON `MyVideos93`.* TO 'kodi'@'192.168.1.%'                                                         |
+------------------------------------------------------------------------------------------------------------------------+
2 rows in set (0.00 sec)

Now restart the RPi, and the new database was created and the data migrated across.

...
18:51:37   9.850684 T:1963544576   ERROR: Unable to open database: MyVideos99 [1049](Unknown database 'MyVideos99')
18:51:37   9.869744 T:1963544576   ERROR: Unable to open database: MyVideos98 [1049](Unknown database 'MyVideos98')
18:51:37   9.899451 T:1963544576   ERROR: Unable to open database: MyVideos97 [1049](Unknown database 'MyVideos97')
18:51:37   9.926645 T:1963544576   ERROR: Unable to open database: MyVideos96 [1049](Unknown database 'MyVideos96')
18:51:37   9.944409 T:1963544576   ERROR: Unable to open database: MyVideos95 [1049](Unknown database 'MyVideos95')
18:51:37   9.971253 T:1963544576   ERROR: Unable to open database: MyVideos94 [1049](Unknown database 'MyVideos94')
18:51:37   9.997427 T:1963544576  NOTICE: Old database found - updating from version 93 to 99
18:51:52  25.252617 T:1963544576  NOTICE: Attempting to update the database MyVideos99 from version 93 to 99
18:52:26  59.282043 T:1963544576  NOTICE: Running database version TV29
18:52:26  59.287502 T:1963544576  NOTICE: Running database version Epg11
...

Then I locked it back down again, but with a slight improvement, as Kodi doesn’t seem to delete the older DB by default.

mysql> REVOKE ALL PRIVILEGES, GRANT OPTION FROM 'kodi'@'192.168.1.%';
Query OK, 0 rows affected (0.02 sec)

mysql> flush privileges;
Query OK, 0 rows affected (0.00 sec)

mysql> show grants for 'kodi'@'192.168.1.%';
+-----------------------------------------------------------------------------------------------------+
| Grants for [email protected].%                                                                            |
+-----------------------------------------------------------------------------------------------------+
| GRANT USAGE ON *.* TO 'kodi'@'192.168.1.%' IDENTIFIED BY PASSWORD '*xxxx' |
+-----------------------------------------------------------------------------------------------------+

mysql> GRANT ALL ON `MyVideos%`.* TO 'kodi'@'192.168.1.%' IDENTIFIED BY 'kodi';
Query OK, 0 rows affected (0.02 sec)

mysql> flush privileges;
Query OK, 0 rows affected (0.02 sec)

mysql> show grants for 'kodi'@'192.168.1.%';
+---------------------------------------------------------------------------------------------------------------+
| Grants for [email protected].%                                                                                   |
+---------------------------------------------------------------------------------------------------------------+
| GRANT USAGE ON *.* TO 'kodi'@'192.168.1.%' IDENTIFIED BY PASSWORD '*xxxx' |
| GRANT ALL PRIVILEGES ON `MyVideos%`.* TO 'kodi'@'192.168.1.%'                                                 |
+---------------------------------------------------------------------------------------------------------------+

And that was that.

Using TV Headend as a PVR client

Minor problem here. The automatic update to a newer client version was failing, and the older client was crashing. Uninstalled the old one, did an install of the newer release, and it was back up and running (existing config was preserved).

 

Win10 keeps waking from sleep

Recently had an issue where Windows 10 (version 1151, build 10586.713) would wake up again about 30 seconds after putting it to sleep.

Fortunately the command powercfg -lastwake will give you the process that is responsible.

In my case it seems that it was related to GoToMeeting. Checking online and this seems to be a more general issue

For me the workaround was easier – I just un-installed GTM until they get this sorted

Remote Desktop Protocol [RDP] and OS X

So, I had occasion to try and connect to a windows machine from my Mac. As a long time windows user, my default goto for this is of course Microsoft’s Remote Desktop Protocol. And as luck would have it, OS X/macOS ships with a client called Remote Desktop Connection for Mac (version 2.1.1 build 110309) though from the copyright notices this looks like it hasn’t been touched since 2010… and that is the problem.

On attempting to connect to anything half way recent e.g. Server 2012, Win10, etc. you are thrown the very helpful error “Remote Desktop Connection cannot verify the identity of the computer that you want to connect to. Try reconnecting to the Windows-based computer, or contact our administrator.”

It turns out that Microsoft improved the security of RDP (always a good thing) to make use of something called Network Level Authentication [NLA]. This happened the same time Windows moved from Terminal Services to Remote Desktop Services.

What’s the difference? When connecting to a Terminal Server, a user starts a session and types in their credentials. When using an RD Session Host server, a user typically enters credentials into a client-side dialog box. NLA forces the client computer to present user credentials for authentication before the server will create a session for that user.

Because of that process, it’s sometimes called “front authentication.” Servers that are running Windows Server 2008/Vista or later, and clients running Windows XP SP3 or later, support NLA. Because NLA relies on a technology called Credential Security Support Provider [CredSSP] Protocol, if you’re using a Remote Desktop Protocol [RDP] client for another OS, you’ll need a client that supports NLA.

Microsoft Remote Desktop Connection Client for Mac doesn’t.

Fortunately there is an alternative that does. Via the AppStore, search for ‘Microsoft Remote Desktop’ – Version 8.0.36 (Build 27228) is what I have today. Install this, try and connect to your Windows machine (Win10 for me) and you are in business.

 

Enabling telnet access on DCS-7110

Very nice outdoor bullet camera that the D-Link DCS-7110 is, managing it is a pain as the main web interface still uses Active-X, and seems to be coded to IE6. Fortunately, it is actually running linux under the hood, so if you know what you are doing, you can edit the configuration directly.

Step 1 is to enable the telnet server, by using this link:

http://<camera-ip>/cgi-bin/admin/mod_inetd.cgi?telnet=on

Now we can telnet onto the device using the same credentials as the web

[user.network][~]=> telnet A.B.C.D
Trying A.B.C.D...
Connected to A.B.C.D.
Escape character is '^]'.

Network-Camera login: <username>
Password:
~ #
~ # ls
back.tar.gz imgbufmgr s0 s1 s2 s3 s4
~ # cd s0
~/s0 # ls

All the interesting config that I could see lives under /etc

~/s0 # cd /
/ # ls
bin drivers home linuxrc proc sbin tmp usr www
dev etc lib mnt root sys tmpfs var

When you are done, be sure to disable the telnet server again, and reboot the camera for the changes to take effect.

http://<camera-ip>/cgi-bin/admin/mod_inetd.cgi?telnet=off


> telnet A.B.C.D
Trying A.B.C.D...
telnet: connect to address A.B.C.D: Connection refused
telnet: Unable to connect to remote host

Host-Guest Networking with macvtap

I’ve been working with a lot of VMs lately and was using the “new” macvtap + bridge mode for the VM networking as this is supposed to offer great performance, while being simpler to configure. A key point is that each macvtap has its own mac address on the same Ethernet segment – think of this as an Ethernet sub-interface. The physical interface to which the macvlan is attached is often referred to as “the lower device”, with the macvtap itself referred to as the “upper device”.

macvtap has a number of different modes that it can be run in;

  • Bridge: this works almost like a traditional bridge, in that data received on a macvlan in bridge mode and destined for another macvlan of the same lower device is sent directly to the target (if the target macvlan is also in bridge mode), rather than being sent outside. Basically no learning, and no STP – simple and fast
  • VEPA: Virtual Ethernet Port Aggregator is the default mode. If the lower device receives data from a macvlan in VEPA mode, this data is always sent “out” to the upstream switch or bridge, even if it’s destined for another macvlan in the same lower device. The benefit to this is that the traffic between VMs becomes visible externally, the downside being that the external switch must support hair-pin mode (a.k.a reflective relay).
  • Private: this is essentially like VEPA mode, but with the added feature that no macvlans on the same lower device can communicate, regardless of where the packets come from – basically think of it as acting like a private VLAN.
  • Passthrough: No idea yet about this mode

There is one big disadvantage to macvlan though – by design it is not possible for the host to connect directly with the guests.

There is however a workaround – we add a new macvtap interface to the host, and route all VM communications through that bridge. Basic steps are;

Create a new macvlan bridge and bring it up

sudo ip link add link eth0 macvlan0 type macvlan mode bridge
sudo ifconfig macvlan0 up
sudo ifconfig macvlan0
macvlan0  Link encap:Ethernet  HWaddr fa:ab:14:97:fd:ec
inet6 addr: fe80::f8ab:14ff:fe97:fdec/64 Scope:Link
UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:6 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:0
RX bytes:0 (0.0 B)  TX bytes:508 (508.0 B)

Assign an IP address to the macvtap interface (192.168.1.3), and add a static host route towards the VM IP (192.168.1.10)

sudo ifconfig macvlan0 192.168.1.3 netmask 255.255.255.0
sudo ip route add 192.168.1.10/32 via 192.168.1.3 dev macvlan0

And there you go – host-guest communications via macvtap interfaces

ping 192.168.1.10
PING 192.168.1.10 (192.168.1.10) 56(84) bytes of data.
64 bytes from 192.168.1.10: icmp_seq=1 ttl=64 time=0.282 ms
64 bytes from 192.168.1.10: icmp_seq=2 ttl=64 time=0.134 ms

The downside to this being;

  1. You lose 1 extra IP address on the host, so it can network to the guest
  2. You have to add a lot of static routes unless you further subnet your network between VM and non-VM hosts, and route the VM subnet through the macvap interface